  page 1 of 6 dc/dc converters tep 100 series, 100 watt features rugged, compact metal case easy chassis mount screw terminal adaptor available for easy connection wide 2:1 input voltage range full load operation up to 60c with convection cooling soft start under voltage lock-out circuit reverse input voltage protection input protection flter 3-year product warranty order code* input voltage output voltage output current max. effciency typ. tep 100-1210 3.3 vdc 25.0 a 90 % tep 100-1211 5.0 vdc 20.0 a 91 % tep 100-1212 9 C 18 vdc 12 vd c 8.4 a 91 % tep 100-1213 (12 vdc nominal) 15 vdc 6.7 a 91 % tep 100-1215 24 vdc 4.2 a 90 % tep 100-1216 28 vdc 3.6 a 90 % tep 100-1218 48 vdc 2.1 a 90 % tep 100-2410 3.3 vdc 25.0 a 91 % tep 100-2411 5.0 vdc 20.0 a 93 % tep 100-2412 18 C 36 vdc 12 vd c 8.4 a 93 % tep 100-2413 15 vdc 6.7 a 93 % tep 100-2415 (24 vdc nominal) 24 vdc 4.2 a 92 % tep 100-2416 28 vdc 3.6 a 92 % tep 100-2418 48 vdc 2.1 a 92 % tep 100-4810 3.3 vdc 25.0 a 91 % tep 100-4811 5.0 vdc 20.0 a 93 % tep 100-4812 12 vd c 8.4 a 93 % tep 100-4813 36 C 75 vdc 15 vdc 6.7 a 93 % tep 100-4815 (48 vdc nominal) 24 vdc 4.2 a 92 % tep 100-4816 28 vdc 3.6 a 92 % tep 100-4818 48 vdc 2.1 a 92 % models (models pictured with chassis mount adaptor and optional heatsink) * C add suffx Ccm , Ccmf for models with chassis mount adaptor, see last page. C add suffx Cn for negative remote control, see page 3 -> remote on/off the tep-100 series is a family of isolated high performance dc-dc converter modules with ultra-wide 2:1 input voltage ranges which come in a rugged, sealed metal case. these converters are suitable for a wide range of applications, but the product is designed particularly also for industrial appli - cations where often no pcb mounting is possible but the module has to be mounted on a chassis. four threaded m3 inserts in the module makes chassis mount or attachment of a heatsink for optimal thermal management very simple. for easy connection there is also an unique adaptor available with screw terminals. a very high effciency allows an operating tempe - rature up to +60c with natural convection cooling without power derating. further features include output voltage trimming, remote on/off and under voltage lockout. the very wide input voltage range and reverse input voltage protection make these converters also an interesting solution for battery operated systems. ul 609 50 -1 http://www.tracopower.com
page 2 of 6 input specifications input current at no load 12 vin; 3.3 C 15 vdc models: 210 ma typ. 12 vin; 24 C 48 vdc models: 100 ma typ. 24 vin; 3.3 C 15 vdc models: 185 ma typ. 24 vin; 24 C 48 vdc models: 85 ma typ. 48 vin; 3.3 C 15 vdc models: 90 ma typ. 48 vin; 24 C 48 vdc models: 40 ma typ. input current at full load 12 vin models: 9.4 a typ. 24 vin models: 4.6 a typ. 48 vin models: 2.3 a typ. start-up voltage 12 vin models: 8.5 vdc (or lower) 24 vin models: 17.5 vdc (or lower) 48 vin models: 35.5 vdc (or lower) under voltage shut down (lock-out circuit) 12 vin models: 7.5 vdc typ. 24 vin models: 16 vdc typ. 48 vin models: 34 vdc typ surge voltage (100 msec. max.) 12 vin models: 36 v max. 24 vin models: 50 v max. 48 vin models: 100 v max. conducted noise en 55022 level a, fcc part 15, level a (chassis mount option Ccfm required) esd (electrostatic discharge) en 61000-4-2, air 8 kv, contact 6 kv, perf. criteria a radiated immunity en 61000-4-3, 10 v/m, perf. criteria a fast transient / surge en 61000-4-4, 2 kv, perf. criteria a en 61000-4-5, 1 kv perf. criteria a with external input capacitor e.g. nippon chemi-con ky 200 f, 100 v, esr 48 mohm or with chassis mount option Ccfm conducted immunity en 61000-4-6, 10 vrms, perf. criteria a reverse voltage protection parallel diode recommended input fuse (slow blow) 12 vin models: 15 a 24 vin models: 10 a 48 vin models: 5 a output specifications voltage set accuracy 1 % output voltage adjustment +10 % / C20 % by external resistor see application note: regulation C input variation vin min. to vin max. 0.2 % max. C load variation (0 C 100 %) 3.3 C 15 vdc models: 0.3 % max. 24 C 48 vdc models: 0.3 % max. temperature coefficient 0.02 %/k minimum load not required remote sense 10 % max. of vout nom. (including trim up value) ripple and noise (20 mhz bandwidth) 3.3 & 5 vdc models: 75 mvpk-pk max. 12 & 15 vdc models: 100 mvpk-pk max. 24 & 28 vdc models: 200 mvpk-pk max. 48 vdc models: 300 mvpk-pk max. dc/dc converters tep 100 series 100 watt http://www.tracopower.com
page 3 of 6 output specifications start up time (nominal vin and constant resistive load) 25 ms typ. (at power on or remote on) transient response (25% load step change) 200 s typ. output current limitation at 110 -140 % of iout max. over voltage protection at 115 -130 % of vout nom. short circuit protection indefinite, automatic recovery capacitive load 3.3 & 5 vdc models: 40000 f max. 12 vdc models: 7000 f max. 15 vdc models: 4460 f max. 24 vdc models: 1750 f max. 28 vdc models: 1280 f max. 48 vdc models: 430 f max. general specifications temperature ranges C operating C40c to +75c C case temperature +105c max. C storage C55c to +125c thermal impedance C without heatsink 6.7c/w C with heatsink 4.7c/w derating see derating graphs page 4 over temperature protection at 115c thermal shock acc. mil-std-810f humidity (non condensing) 95 % rel h max. reliability, calculated mtbf (mil-hdbk-217f, at +25c, ground benign) 75000 h isolation voltage (60sec.) C input/output 2250 vdc (basic insulation) C input/case 1500 vdc isolation capacitance C input/output 2500 pf max. isolation resistance C input/output (500 vdc) >1 gohm min. switching frequency 300 khz typ. (puls width modulation) safety standards ul 60950-1 , iec/en 60950-1 safety approvals C ul/cul www.ul.com -> certifications -> file e188913 remote on/off C positive logic (standard) C on: 3 to 12 vdc or open circuit C off: 0 to 1.2 vdc or short circuit pin 1 and 3 C negative logic (option -n ) C on: 0 to 1.2 vdc or short circuit pin 1 and 3 C off: 3 to 12 vdc or open circuit C off idle current: 3 ma environmental compliance C reach www.tracopower.com/products/tep100-reach.pdf C rohs rohs directive 2011/65/eu dc/dc converters tep 100 series 100 watt application note: www.tracopower.com/products/tep100-application.pdf http://www.tracopower.com all specifcations valid at nominal input voltage, full load and +25c after warm-up time unless otherwise stated.
page 4 of 6 dc/dc converters tep 100 series 100 watt output power derating 24 vin models: output 3.3C15 vdc 24 vin models: output 24C48 vdc models with heatsink models without heatsink 48 vin models: output 3.3C15 vdc 48 vin models: output 24C48 vdc 24 vin models: output 3.3C15 vdc 24 vin models: output 24C48 vdc 48 vin models: output 3.3C15 vdc 48 vin models: output 24C48 vdc http://www.tracopower.com
page 5 of 6 0.20 0.5 0.023 2.40 2.00 0.30 0.70 1.00 1.90 0.19 2.28 (57.9) 1 2 3 4 5 6 8 9 7 4 x m3 thd (48.26) (4.8) (50.80) (61.0) (17.78) (12.7) (25.40) bottom view (7.62) (0.6) (5.1) (trough hole) dc/dc converters tep 100 series 100 watt t op view 0.95 0.45 (24.2) (11.4) 2.40 (61.0) 2.28 (57.9) tep 100 module dimensions in inch, () = mm tolerances: 0.02 (0.5) pin pich tolerances: 0.01 (0.25) mounting hole pich tolerances: 0.01 (0.25) weight: 97 g (3.42 oz) pin 1 C vin 2 case 3 remote on/off 4 + vin 5 C vout 6 C sense* 7 trim 8 + sense* 9 + vout pin-out *sense line to be connected to the output either at the module or at the load under regard of polarity. weight: 135 g (4.76 oz) (heatsink + converter) order code: tep-hs1 includes heatsink with termal pad and mounting screws for to order modules with mounted heatsink ask factory. pin diameter pin 5 & 9: 0.08 (2.0) pin diameter other pins: 0.04 (1.0) tep-hs1 heatsink (pictured with heatsink mounted) specifications casing material metal potting material silicone (ul94v-0 rated) base material fr4 vibration acc. mil-std-810f dimensions http://www.tracopower.com
page 6 of 6 chassis mount adaptor dc/dc converters tep 100 series 100 watt rev. october 11. 2013 1.27 0.68 (32.3) (17.3) 1.47 0.68 (37.3) (17.3) 1.60 (40.6) 3.35 3.071 (85.0) (78.0) 2.40 2.126 (61.0) (54.0) 0.14 (3.5) 0.14 (3.5) 4 x ? 0.17 (4.3) 2.00 (50.8) 0.89 (22.2) tep 100 module with chassis mount adabtor (suffx Ccm or Ccmf) suffix Ccm: chassis mount adaptor dimensions in inch, () = mm tolerances 0.02 (0.5) mounting hole pich tolerances 0.01 (0.25) connection *sense line to be connected to the output either at the module or at the load under regard of polarity. please note that adaptors cannot be ordered as seperate items but are factory assembled. suffix Ccmf: chassis mount adaptor with emi filter for easy chassis mounting the converter modules can be supplied with an adaptor option consisting of a screw terminal connection board (soldered to converter pins)and a chassis mount adaptor. in addition this chassis mount option is available with an emi-filter(see emi specification) weight: Ccm 196 g (6.91 oz) weight: Ccmf 238 g (8.39 oz) pin 1 C vin 2 case 3 remote on/off 4 + vin 5 C vout 6 C sense* 7 trim 8 + sense* 9 + vout sp ec i?cati ons can be changed wi thout noti ce! make sure you are using the latest documentation, downloadable at www.tracopower. com www .tracopower. com


▲Up To Search▲   

 
Price & Availability of TEP1004813

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X